The Adwa AD3000 is a professional laboratory conductivity, TDS and temperature bench meter designed for accurate water quality measurement and routine laboratory analysis. It combines a wide measurement range, automatic temperature compensation, flexible calibration options, GLP functionality and data storage in a reliable benchtop design.
The AD3000 measures electrical conductivity from 0.00 µS/cm up to 199.9 mS/cm across multiple automatically selected ranges. Its TDS measurement range extends from 0.00 ppm to 99.9 ppt, allowing the meter to be used for different water-quality and laboratory applications.
The meter features a selectable TDS conversion factor from 0.40 to 1.00, with 0.50 as the default value. Conductivity calibration includes zero-point offset calibration and one-point slope calibration using memorized standard values or a custom calibration value.
Temperature can be measured from -9.9 to 120.0°C with a resolution of 0.1°C. The supplied AD76309 EC probe includes a built-in temperature sensor for convenient measurement and temperature compensation.
The AD3000 can store up to 250 on-demand samples, making it useful for laboratory testing, quality control, water treatment and other applications requiring conductivity and TDS monitoring.
Key Features
- Professional conductivity, TDS and temperature bench meter
- Wide conductivity measurement range up to 199.9 mS/cm
- TDS measurement up to 99.9 ppt
- Selectable TDS factor from 0.40 to 1.00
- Default TDS factor of 0.50
- Automatic temperature compensation
- Built-in temperature sensor in EC probe
- Flexible conductivity calibration
- Six memorized conductivity calibration values
- Custom calibration value option
- Memory for up to 250 on-demand samples
- GLP functionality
- 12V DC power supply
Specifications
| Specification | Details |
| EC Range | 0.00–19.99 µS/cm; 20.0–199.9 µS/cm; 200–1999 µS/cm; 2.00–19.99 mS/cm; 20.0–199.9 mS/cm |
| TDS Range | 0.00–9.99 ppm; 10.0–99.9 ppm; 100–999 ppm; 1.00–9.99 ppt; 10.0–99.9 ppt |
| Temperature Range | -9.9 to 120.0°C |
| EC/TDS Resolution | 0.01, 0.1, 1 µS/cm (ppm); 0.01, 0.1 mS/cm (ppt) |
| Temperature Resolution | 0.1°C |
| EC/TDS Accuracy | ±1% F.S. |
| Temperature Accuracy | ±0.5°C |
| EC Calibration | Offset at 0.00 µS/cm; 1-point slope calibration |
| Memorized Calibration Values | 84.0, 1413 µS/cm; 5.00, 12.88, 80.0, 111.8 mS/cm |
| TDS Factor | Selectable 0.40–1.00; default 0.50 |
| Memory | Up to 250 samples |
| Probe | AD76309 EC probe with built-in temperature sensor |
| Power Supply | 12V DC adapter |